Processing as a Hydrophobic Sealing Agent for Concrete: The work performed (preparing the concrete surface, setting up a reference surface, application and quality control) must follow the applicable regulations.
- Concrete should not be sealed until at least 28 days after it has been produced so that the setting of the cement is not affected.
- New surfaces that are still unsoiled must be cleansed of coarse particles and dust deposits by sweeping or, if necessary, using compressed air. Surfaces already weathered, and those heavily soiled by oil, rubber residue, etc., must first be cleaned using superheated steam or high-pressure water before commencing treatment. It is imperative that the water used be siphoned off immediately to prevent saturation of the concrete.
- Impregnation should always be performed on superficially dry concrete, i.e., when the surface of the concrete appears evenly dry, no more damp patches are visible and the moisture content equilibrium is established. To this end, moisture in the surface zone of the concrete is measured using a suitable technique.The surface-zone moisture content of the concrete (from the surface to a depth of 20 mm) should not exceed 4 wt%.
- Evenly apply the sealer to the building material in two coats, wet-on-wet. The two coats are absolutely essential to prevent the formation of defects in the impregnated surface. Do not allow puddles to form. The sealer is applied by flow coating at reduced pressure (1-2 bar). A lambskin roller may be used afterward for more even coverage. - In the event of unexpected rain, cover surfaces already sealed and halt all further sealing.
SILRES® BS 17040 US should not get into direct contact with bitumen. The resistance of insulant against SILRES® BS 17040 US has to be determined dependend on temperature.
Processing as a Concrete Admixture (Hydrophobic Admixture) The recommended admixture range of a 1 : 3 dilution of SILRES® BS 17040 US is 1.0 % to 5.0 % of the cement content. A significant reduction in water uptake can already be achieved at a concentration of 1.0 % of the cement. SILRES® BS 17040 US is added either simultaneously with or immediately after the mixing water – it should never be added along with other additives. To keep a constant w/c value the total mixing water is reduced by amount required earlier for dilution. We recommend testing compatibility with other concrete admixtures separately. A longer mixing time will thoroughly distribute the product within the overall system, which in turn will make it highly effective. When used in concrete goods or similar concrete products according to EN 1338, 1339 or EN 1340, an initial-type test (cf. section 6.2 of the respective standard) is recommended.
SILRES® BS 17040 US is recommended for the hydrophobic sealing and priming of concrete and reinforced concrete in road, bridge and building construction as well as water resisting admixtures for non-load bearing manufactured concrete products.