This content is for Brazil. Our system has detected that you are from United States. Do you want to set United States as your new country?

This product is not available in Brazil. Please use the product search or contact us.

GENIOSIL® NOTE CE

GENIOSIL® NOTE CE is n-Octyltriethoxysilane.
GENIOSIL® NOTE CE is used in undiluted form for the hydrophobic priming and impregnation of concrete and reinforced concrete.
In addition GENIOSIL® NOTE CE is suitable for the hydrophobic treatment of fillers and pigments.


  • Empirical formula C14H32O3Si
  • Molecular weight 276,49

Properties

 GENIOSIL® NOTE CE is characterised by:

  • Excellent penetrating power
  • solvent free, environmentally compatible
  • low volatility

Treated concrete will have the following permanent properties:

  • dramatic reduction in water and water diluted salt absorption (e.g.: chlorides and sulfates) 
  • high level of breathability
  • improved durability against freeze-thaw de-icing salt stress
  • enhanced durability
  • provides good adhesion for paints

In the construction material GENIOSIL® NOTE CE reacts with atmospheric moisture and / or the water in the building material’s pores, eliminating alcohol. The active thus substance formed greatly reduces the concrete’s absorbency in the active zone (penetration depth after post treatment), but without blocking any pores or capillaries. The impregnated building material retains very high water-vapor permeability.

The work performed (preparing the concrete surface, setting up a reference surface, application and quality control) must follow the applicable regulations (in Germany these are the DAfStb repair work guidelines and the ZTV-ING).

- Concrete should not be treated until at least four weeks after it has been produced so that the setting of the cement is not affected.

- New surfaces that are still unsoiled must be cleansed of coarse particles and dust deposits by sweeping or, if necessary, using compressed air. Surfaces already weathered, and those heavily soiled by oil, rubber residue, etc., must first be cleaned using superheated steam or high-pressure water before commencing treatment. It is imperative that the water used be siphoned off immediately to prevent saturation of the concrete.

- Hydrophobic Impregnation should always be performed on superficially dry concrete, i.e., when the surface of the concrete appears evenly dry, no more damp patches are visible and the moisture content equilibrium is established. To this end, moisture in the surface zone of the concrete is measured using a suitable technique (CM method or other methods allowed under ZTV-ING). The surface-zone moisture content of the concrete (from the surface to a depth of 20 mm) should not exceed 4 wt%.

- Evenly apply the hydrophobic impregnating agent to the building material in several coats, wet-on-wet. Do not allow puddles to form. The impregnating agent is applied by flow coating at reduced pressure. A lambskin roller may be used afterward for more even coverage.

- In the event of unexpected rain, cover surfaces already impregnated and halt all further impregnation.

- GENIOSIL® NOTE CE should never come in direct contact with bitumen. The resistance of insulating materials to GENIOSIL® NOTE CE must be tested on a case-by-case basis for the required temperatures.

GENIOSIL® NOTE CE is recommended for the hydrophobic impregnation and priming of concrete and reinforced concrete in road, bridge and building construction. In addition it is suitable for the hydrophobic treatment of fillers and pigments.

Expert opinions:

The effectiveness of GENIOSIL® NOTE CE is confirmed
and documented in the following laboratory reports:

• Kiwa GmbH Polymer institut, Flörsheim, Germany
Test report EN 1504-2 HI:
P 13491-1, 21.06.2023

• Kiwa GmbH Polymer institut, Flörsheim, Germany
Test report NT BUILD 515:
P 13893a, 08.02.2023

Packaging

Information on available container sizes is obtainable from WACKER subsidiaries.

Storage

The containers must be protected against sunlight. The 'Best use before end' date of each batch is shown on the product label. Storage beyond the date specified on the label does not necessarily mean that the product is no longer usable. In this case however, the properties required for the intended use must be checked for quality assurance reasons.

 

 

Registration (selected countries / regions)

 

Listed on or in accordance with the following

inventories:

EINECS – Europe

ECL – Korea

ENCS – Japan

AICS – Australia

IECSC – China

DSL – Canada

PICCS – Philippines

TSCA – USA

Sales and support

Wacker Quimica do Brasil Ltda.
Rua Municipal, 325
06612-060 Jandira
Brazil
+55  11  4789-8300 (Phone)
+55 11 4789-8345  (Fax)
Contact
Website

How can we help you?

  • Do you need help in choosing a product or do you require technical support? If so, please contact our experts.
Ask a question

More products

Please choose an application for viewing your product matches.

Order

My media


Sales Contact

Wacker Quimica do Brasil Ltda.
Rua Municipal, 325
06612-060 Jandira
+55  11  4789-8300 (Phone)

My favorites

My products